AIRBORNE FIELD MILL
PROJECT
KENNEDY SPACE
CENTER
SYNTHESIS FOR JUNE 10, 2001 - ABFM
Flight Summary (Anvil Day)
Case 1 (Times: 2008 - 2042)
|
Type of case | cumulul |
| Complexity | moderate |
| Convection | line of convection |
Electric field
kV/m | Min Em_m = 0.030
Max Em_m = 39.706
Mean Em_m = 5.283 |
Microphysics
#/Liter |
Max CON_FSSP = 138412.031
Mean CON_FSSP = 14458.293
|
Max Tot_con_1DC = 1268.559
Mean Tot_con_1DC = 190.094
|
Max Tot_con_2DC = 1009.222
Mean Tot_con_2DC = 41.151
|
Max 2DC_100_400 = 404.581
Mean 2DC_100_400 = 19.885
|
Max 2DC_400_1000 = 40.526
Mean 2DC_400_1000 = 2.683
|
Max 2DC_GT_1000 = 2.178
Mean 2DC_GT_1000 = 0.080
|
|
| Location | (x,y) ~ (30,30) |
| Storm Motion |
9.8 m/s east, 4 m/s south gives: 10.6 m/s SE |
Brief Description |
A little bit of anvil at 2025, and some low level stuff at takeoff.
Mostly this time fram is around convection with a lot of lightning.
|
Case 2 (Times: 2042 - 2133)
|
Type of case | (mostly) anvil |
| Complexity | moderate |
| Convection | line of convection |
Electric field
kV/m | Min Em_m = 0.311
Max Em_m = 37.842
Mean Em_m = 7.159 |
Microphysics
#/Liter |
Min CON_FSSP = 784.239
Max CON_FSSP = 37283.641
Mean CON_FSSP = 7012.018
|
Min Tot_con_1DC = 2.310
Max Tot_con_1DC = 564.800
Mean Tot_con_1DC = 66.621
|
Max Tot_con_2DC = 904.172
Mean Tot_con_2DC = 84.221
|
Max 2DC_100_400 = 332.611
Mean 2DC_100_400 = 39.660
|
Max 2DC_400_1000 = 41.171
Mean 2DC_400_1000 = 7.497
|
Max 2DC_GT_1000 = 3.481
Mean 2DC_GT_1000 = 0.594
|
|
| Location | (x,y) ~ (80,80) |
| Storm Motion |
9.8 m/s east, 4 m/s south gives: 10.6 m/s SE |
Brief Description | Much of this is flown very
close to the source.
|
Case 3 (Times: 2133 - 2210)
|
Type of case | debris |
| Complexity | moderate |
| Convection | line of convection |
Electric field
kV/m | Min Em_m = 0.181
Max Em_m = 46.569
Mean Em_m = 14.614 |
Microphysics
#/Liter |
Min CON_FSSP = 26.798
Max CON_FSSP = 14182.765
Mean CON_FSSP = 4492.827
|
Min Tot_con_1DC = 0.941
Max Tot_con_1DC = 128.683
Mean Tot_con_1DC = 31.707
|
Max Tot_con_2DC = 198.598
Mean Tot_con_2DC = 39.747
|
Max 2DC_100_400 = 87.937
Mean 2DC_100_400 = 16.218
|
Max 2DC_400_1000 = 23.683
Mean 2DC_400_1000 = 5.296
|
Max 2DC_GT_1000 = 2.220
Mean 2DC_GT_1000 = 0.642
|
|
| Location | (x,y) ~ (100,60) |
| Storm Motion |
9.8 m/s east, 4 m/s south gives: 10.6 m/s SE |
Brief Description | There was lightning
associated with this part of the cloud about 2109 and bases are at
leaste down to the 4km level. The last lightning in
this part of the line was about 2130.
|
Case 4 (Times: 2210 - 2311)
|
Type of case | anvil |
| Complexity | moderate |
| Convection | line of convection |
Electric field
kV/m | Min Em_m = 0.147
Max Em_m = 47.495
Mean Em_m = 7.360 |
Microphysics
#/Liter |
Max CON_FSSP = 11823.322
Mean CON_FSSP = 2692.819
|
Max Tot_con_1DC = 128.045
Mean Tot_con_1DC = 32.181
|
Max Tot_con_2DC = 177.538
Mean Tot_con_2DC = 37.561
|
Max 2DC_100_400 = 87.054
Mean 2DC_100_400 = 17.014
|
Max 2DC_400_1000 = 27.712
Mean 2DC_400_1000 = 5.735
|
Max 2DC_GT_1000 = 2.867
Mean 2DC_GT_1000 = 0.380
|
|
| Location | (x,y) ~ (130,90) |
| Storm Motion |
9.8 m/s east, 4 m/s south gives: 10.6 m/s SE |
Brief Description | The aircraft does get
close to the source about 2237 and 2240.
|
Case 5 (Times: 2311 - 2345)
|
Type of case | cumulus |
| Complexity | moderate |
| Convection | line of convection |
Electric field
kV/m | Min Em_m = 0.185
Max Em_m = 23.100
Mean Em_m = 3.097 |
Microphysics
#/Liter |
Max CON_FSSP = 53789.430
Mean CON_FSSP = 2115.661
|
Max Tot_con_1DC = 129.859
Mean Tot_con_1DC = 9.684
|
Max Tot_con_2DC = 74.270
Mean Tot_con_2DC = 4.772
|
Max 2DC_100_400 = 41.491
Mean 2DC_100_400 = 2.092
|
Max 2DC_400_1000 = 10.217
Mean 2DC_400_1000 = 0.672
|
Max 2DC_GT_1000 = 0.574
Mean 2DC_GT_1000 = 0.037
|
|
| Location | (x,y) ~ (20,50) |
| Storm Motion |
9.8 m/s east, 4 m/s south gives: 10.6 m/s SE |
Brief Description | Landing.
|
Animation of this line shows a due-East motion, but if you look at
individual cells (as I did to determine the storm motion) there is
a slight southern motion.
SYNTHESIS FOR JUNE 10, 2001 - ABFM
Investigator: A. Grainger
[presented on Jan 10, 2002]
Reflectivity
Electric Field
The information provided here and made accessible from this page is the
responsibility of the author. The opinions and work discussed on this page
are those of the individual and do not necessarily represent the views of UCAR.
Copyright © UCAR 2000 -